Company Details

  • Changchun Medicon Technology Development Co., Ltd

  •  [Jilin,China]
  • Business Type:Distributor/Wholesaler , Manufacturer , Trade Company
  • Main Mark: Africa , Americas , Asia , Caribbean , East Europe , Europe , Middle East , North Europe , Oceania , Other Markets , Worldwide
  • Exporter:71% - 80%
  • Certs:ISO13485, ISO9001, FDA, TUV, CE
  • Description:Accurate 5 Parameter Urine Test Strips,Check Urine Test Strips 5 Parameter,MDK Accurate Urinalysis Test Strips
Inquiry Basket ( 0 )

Changchun Medicon Technology Development Co., Ltd

Accurate 5 Parameter Urine Test Strips,Check Urine Test Strips 5 Parameter,MDK Accurate Urinalysis Test Strips

86-431-81976357

Home > Products > Clinical Analytical Instruments > Urine Reagent Test Strips > MDK urinalysis strips 5 parameters FDA CE

MDK urinalysis strips 5 parameters FDA CE

Share to:  
    Payment Type: L/C,T/T,D/P,Paypal,Money Gram,Western Union
    Incoterm: FOB,CFR,CIF,EXW,FCA,CPT,CIP
    Delivery Time: 10 Days

Basic Info

Model No.: MEURS5-0802

Additional Info

Transportation: Ocean,Land,Air

Port: Shanghai,Dalian,Shenzhen

Product Description

Product Introduction

Nitrite: This test is specific for nitrite in urine. The test is specific for nitrite and will not react with any other substance normally excreted in the urine. Pink spots or pink edges should not be interpreted as a positive result.

Protein: The test area is more sensitive to albumin than to globulins, hemoglobin, Bence-Jones protein and mucoprotein; a [Negative" result does not rule out the presence of other proteins.

Blood: The significance of the [Trace" reaction may vary among patients, and clinical judgment is required for assessment in each individual case. Development of green spots or green color on the reagent area within 60 seconds indicates the need for further investigation.

Specific Gravity: This test reflects the ion concentration of urine and correlates well with the refractometric method. If pH is equal to or greater than 6.5, then add 0.005 to SG obtained.

Glucose: The test is specific for glucose; no substance excreted in the urine other than glucose is known to give a positive result. In diluted urine containing less than 0.3mmol/L ascorbic acid, as little as 2.2mmol/L of glucose, may produce a color change that might be interpreted as positive.

Product Parameter

Item Sensitivity Analyzer Range Visual Range
Glucose 2.8-5.5 Neg.-55 Neg.-55
PH - 5.0-9.0 5.0-8.5
Protein 0.15-0.3 Neg.-3.0 Neg.20
Ketone 0.5-1.0 Neg.-7.8 Neg.-1.6
Blood 5-15 Neg.-200 Neg.-200
HTB1MRQLJ7KWBuNjy1zjq6AOypXaG.jpg_.webp

Specimen collection & Procedure

1.Use a fresh urine specimen and place it into a clean,dry container.Do not centrifuge test within two hours.If not possible,refrigerate and restore to room temperature before testing.

2.Remove one strip from the bottle and replace the cap tightly immediately.Briefly immerse all reagent areas into the specimen.Wipe off excess urine on the rim of the container.

Then lightly dab off the residual urine with a piece of tissue paper at the rim of the strip.

3.Hold strip in vertical position.Refer to the bottle label for specific reagent areas on the test strip.

Compare the test areas with the color scale on the label.Proper readinng times are critical for optimal results.

See each reagent time as indicated on bottle label.

Coloration appearing only along the edges of the test,or developing after more than two minutes,has no diagnostic value.

The reagent strips must be kept in the bottle with the cap tightly closed to maintain reagent reactivity.

Place refer to bottle label for specific reading time for each reagent.

Rapid Urine Test Strips URS-5

Urine Test strips for glucose ph protein ketone blood test strips

Either accurately measure your glucose ph protein test strips in your urine

These are good for 2 years sealed.Once opened,they are best if used within 60-90 days.

Attention

1.Store at temperature between 2-30℃(36-86℉). and out of direct sunlight.

2.Replace cap immediately and tightly after taking out strips.

3.Do not touch test areas

4.Do not remove desicant from bottle.

5.Use it within the expiration date.

6.Read inusert carefully before use.

UTB8f6PGh0nJXKJkSaiyq6AhwXXaM.jpg_.webp (1)

HTB1IcgzBIyYBuNkSnfo763WgVXaM.png_.webp

HTB1PLRjXOjrK1RjSsplq6xHmVXat.jpg_.webp

Certificate

F9657deccb701da4fbf7b73539

Company Profile

A4764ac98de36eb5c65e281126

Utb8oixnbodexkjk43oq763z3xxay Png Webp

FAQ

E5d4810ae8ce4a34c4d3fb9432

Looking for ideal Accurate 5 Parameter Urine Test Strips Manufacturer & supplier ? We have a wide selection at great prices to help you get creative. All the Check Urine Test Strips 5 Parameter are quality guaranteed. We are China Origin Factory of MDK Accurate Urinalysis Test Strips. If you have any question, please feel free to contact us.

Product Categories : Clinical Analytical Instruments > Urine Reagent Test Strips

Email to this supplier
  • *Subject:
  • *Messages:
    Your message must be between 20-8000 characters
Communicate with Supplier?Supplier
Aileen Ms. Aileen
What can I do for you?
Contact Supplier